9 Products: Page 1 of 1
 
1
SKU   700-157
Your Price   $235.00
Qty
Product  

AmerCable Wire 10AWG Double-Insulated Black Cable (PV WIRE) - 500FT. Reel

Product Summary   AmerCable Wire 10awg White Cable Features Scope: This specification describes single conductor crosslinked polyethylene (XLP or XLPE) Type RHW-2 and USE-2 for use at 600 volts or less. It is approved per the NEC for DIRECT BURIAL, general-purpose lighting, and power applications at a maximum continuous operating temperature of 90 degrees C in wet and dry locations. Note: VW-1 available when required. Applicable Standards: ASTM B-1, B-3, and B-8 for copper conductors. ICEA S-95-658/NEMA WC70, ICEA S-66-524/NEMA WC7 Cross Linked Polyethylene Insulated Wire&Cable, UL 854 for Service Entrance Cables (incl. Para. 854-38.7 for 300 hr. sunlight resistance) and UL 44 for Thermoset Insulated Wires & Cables, Fed Spec J-C-30B, FAA L-824 Type C 600V Connductors: The single copper conductors shall be solid or stranded annealed or hard uncoated copper per UL83 and ASTM requirements. Insulation: The conductor shall be insulated with XLP or XLP-VW-1 as specified and applied tightly to the conductor in a concentric manner. These conductors are “Oil and Gasoline Resistant II”. All black insulation is rated and identified “Sunlight Resistant”. The minimum at any point shall not be less than 90% of the specified average thickness in compliance with UL 44. Identification: The wire shall be identified in compliance with UL requirements by surface marking indicating the manufacturer, conductor size, voltage rating, UL symbol, and type designation.
2
SKU   700-158
Your Price   $245.00
Qty
Product  

Kris-Tech Wire 10awg (USE-2) Black Cable 500ft. reel

 

Product Summary   Kris-Tech Wire 10awg 7 strands of bare copper XLP RHH RHW-2 USE-2 600V Black
3
SKU   700-207
Your Price   $990.00
Qty
Product  

AmerCable Wire 10AWG Double-Insulated Black Cable (PV WIRE) - 2500FT. Reel

Product Summary   AmerCable Wire 10awg White Cable Features Scope: This specification describes single conductor crosslinked polyethylene (XLP or XLPE) Type RHW-2 and USE-2 for use at 600 volts or less. It is approved per the NEC for DIRECT BURIAL, general-purpose lighting, and power applications at a maximum continuous operating temperature of 90 degrees C in wet and dry locations. Note: VW-1 available when required. Applicable Standards: ASTM B-1, B-3, and B-8 for copper conductors. ICEA S-95-658/NEMA WC70, ICEA S-66-524/NEMA WC7 Cross Linked Polyethylene Insulated Wire&Cable, UL 854 for Service Entrance Cables (incl. Para. 854-38.7 for 300 hr. sunlight resistance) and UL 44 for Thermoset Insulated Wires & Cables, Fed Spec J-C-30B, FAA L-824 Type C 600V Connductors: The single copper conductors shall be solid or stranded annealed or hard uncoated copper per UL83 and ASTM requirements. Insulation: The conductor shall be insulated with XLP or XLP-VW-1 as specified and applied tightly to the conductor in a concentric manner. These conductors are “Oil and Gasoline Resistant II”. All black insulation is rated and identified “Sunlight Resistant”. The minimum at any point shall not be less than 90% of the specified average thickness in compliance with UL 44. Identification: The wire shall be identified in compliance with UL requirements by surface marking indicating the manufacturer, conductor size, voltage rating, UL symbol, and type designation.
4
SKU   700-208
Your Price   $950.00
Qty
Product  

AmerCable Wire 10AWG Single-Insulated (red/black/white) (PV WIRE) - 2500FT. Reel

Product Summary   PLEASE SPECIFY COLOR. AmerCable Wire 10awg White Cable Features Scope: This specification describes single conductor crosslinked polyethylene (XLP or XLPE) Type RHW-2 and USE-2 for use at 600 volts or less. It is approved per the NEC for DIRECT BURIAL, general-purpose lighting, and power applications at a maximum continuous operating temperature of 90 degrees C in wet and dry locations. Note: VW-1 available when required. Applicable Standards: ASTM B-1, B-3, and B-8 for copper conductors. ICEA S-95-658/NEMA WC70, ICEA S-66-524/NEMA WC7 Cross Linked Polyethylene Insulated Wire&Cable, UL 854 for Service Entrance Cables (incl. Para. 854-38.7 for 300 hr. sunlight resistance) and UL 44 for Thermoset Insulated Wires & Cables, Fed Spec J-C-30B, FAA L-824 Type C 600V Connductors: The single copper conductors shall be solid or stranded annealed or hard uncoated copper per UL83 and ASTM requirements. Insulation: The conductor shall be insulated with XLP or XLP-VW-1 as specified and applied tightly to the conductor in a concentric manner. These conductors are “Oil and Gasoline Resistant II”. All black insulation is rated and identified “Sunlight Resistant”. The minimum at any point shall not be less than 90% of the specified average thickness in compliance with UL 44. Identification: The wire shall be identified in compliance with UL requirements by surface marking indicating the manufacturer, conductor size, voltage rating, UL symbol, and type designation. AmerCable Wire 10awg White Cable Features Scope: This specification describes single conductor crosslinked polyethylene (XLP or XLPE) Type RHW-2 and USE-2 for use at 600 volts or less. It is approved per the NEC for DIRECT BURIAL, general-purpose lighting, and power applications at a maximum continuous operating temperature of 90 degrees C in wet and dry locations. Note: VW-1 available when required. Applicable Standards: ASTM B-1, B-3, and B-8 for copper conductors. ICEA S-95-658/NEMA WC70, ICEA S-66-524/NEMA WC7 Cross Linked Polyethylene Insulated Wire&Cable, UL 854 for Service Entrance Cables (incl. Para. 854-38.7 for 300 hr. sunlight resistance) and UL 44 for Thermoset Insulated Wires & Cables, Fed Spec J-C-30B, FAA L-824 Type C 600V Connductors: The single copper conductors shall be solid or stranded annealed or hard uncoated copper per UL83 and ASTM requirements. Insulation: The conductor shall be insulated with XLP or XLP-VW-1 as specified and applied tightly to the conductor in a concentric manner. These conductors are “Oil and Gasoline Resistant II”. All black insulation is rated and identified “Sunlight Resistant”. The minimum at any point shall not be less than 90% of the specified average thickness in compliance with UL 44. Identification: The wire shall be identified in compliance with UL requirements by surface marking indicating the manufacturer, conductor size, voltage rating, UL symbol, and type designation.
5
SKU   700-209
Your Price   $235.00
Qty
Product  

AmerCable Wire 10AWG Single-Insulated (red/black/white) (PV WIRE) - 500FT. Reel

Product Summary   PLEASE SPECIFY COLOR. AmerCable Wire 10awg White Cable Features Scope: This specification describes single conductor crosslinked polyethylene (XLP or XLPE) Type RHW-2 and USE-2 for use at 600 volts or less. It is approved per the NEC for DIRECT BURIAL, general-purpose lighting, and power applications at a maximum continuous operating temperature of 90 degrees C in wet and dry locations. Note: VW-1 available when required. Applicable Standards: ASTM B-1, B-3, and B-8 for copper conductors. ICEA S-95-658/NEMA WC70, ICEA S-66-524/NEMA WC7 Cross Linked Polyethylene Insulated Wire&Cable, UL 854 for Service Entrance Cables (incl. Para. 854-38.7 for 300 hr. sunlight resistance) and UL 44 for Thermoset Insulated Wires & Cables, Fed Spec J-C-30B, FAA L-824 Type C 600V Connductors: The single copper conductors shall be solid or stranded annealed or hard uncoated copper per UL83 and ASTM requirements. Insulation: The conductor shall be insulated with XLP or XLP-VW-1 as specified and applied tightly to the conductor in a concentric manner. These conductors are “Oil and Gasoline Resistant II”. All black insulation is rated and identified “Sunlight Resistant”. The minimum at any point shall not be less than 90% of the specified average thickness in compliance with UL 44. Identification: The wire shall be identified in compliance with UL requirements by surface marking indicating the manufacturer, conductor size, voltage rating, UL symbol, and type designation. AmerCable Wire 10awg White Cable Features Scope: This specification describes single conductor crosslinked polyethylene (XLP or XLPE) Type RHW-2 and USE-2 for use at 600 volts or less. It is approved per the NEC for DIRECT BURIAL, general-purpose lighting, and power applications at a maximum continuous operating temperature of 90 degrees C in wet and dry locations. Note: VW-1 available when required. Applicable Standards: ASTM B-1, B-3, and B-8 for copper conductors. ICEA S-95-658/NEMA WC70, ICEA S-66-524/NEMA WC7 Cross Linked Polyethylene Insulated Wire&Cable, UL 854 for Service Entrance Cables (incl. Para. 854-38.7 for 300 hr. sunlight resistance) and UL 44 for Thermoset Insulated Wires & Cables, Fed Spec J-C-30B, FAA L-824 Type C 600V Connductors: The single copper conductors shall be solid or stranded annealed or hard uncoated copper per UL83 and ASTM requirements. Insulation: The conductor shall be insulated with XLP or XLP-VW-1 as specified and applied tightly to the conductor in a concentric manner. These conductors are “Oil and Gasoline Resistant II”. All black insulation is rated and identified “Sunlight Resistant”. The minimum at any point shall not be less than 90% of the specified average thickness in compliance with UL 44. Identification: The wire shall be identified in compliance with UL requirements by surface marking indicating the manufacturer, conductor size, voltage rating, UL symbol, and type designation.
6
SKU   700-210
Your Price   $918.00
Qty
Product  

AmerCable Wire 10AWG Single-Insulated (red/black/white) (USE-2) - 2500FT. Reel

Product Summary   PLEASE SPECIFY COLOR. AmerCable Wire 10awg White Cable Features Scope: This specification describes single conductor crosslinked polyethylene (XLP or XLPE) Type RHW-2 and USE-2 for use at 600 volts or less. It is approved per the NEC for DIRECT BURIAL, general-purpose lighting, and power applications at a maximum continuous operating temperature of 90 degrees C in wet and dry locations. Note: VW-1 available when required. Applicable Standards: ASTM B-1, B-3, and B-8 for copper conductors. ICEA S-95-658/NEMA WC70, ICEA S-66-524/NEMA WC7 Cross Linked Polyethylene Insulated Wire&Cable, UL 854 for Service Entrance Cables (incl. Para. 854-38.7 for 300 hr. sunlight resistance) and UL 44 for Thermoset Insulated Wires & Cables, Fed Spec J-C-30B, FAA L-824 Type C 600V Connductors: The single copper conductors shall be solid or stranded annealed or hard uncoated copper per UL83 and ASTM requirements. Insulation: The conductor shall be insulated with XLP or XLP-VW-1 as specified and applied tightly to the conductor in a concentric manner. These conductors are “Oil and Gasoline Resistant II”. All black insulation is rated and identified “Sunlight Resistant”. The minimum at any point shall not be less than 90% of the specified average thickness in compliance with UL 44. Identification: The wire shall be identified in compliance with UL requirements by surface marking indicating the manufacturer, conductor size, voltage rating, UL symbol, and type designation. AmerCable Wire 10awg White Cable Features Scope: This specification describes single conductor crosslinked polyethylene (XLP or XLPE) Type RHW-2 and USE-2 for use at 600 volts or less. It is approved per the NEC for DIRECT BURIAL, general-purpose lighting, and power applications at a maximum continuous operating temperature of 90 degrees C in wet and dry locations. Note: VW-1 available when required. Applicable Standards: ASTM B-1, B-3, and B-8 for copper conductors. ICEA S-95-658/NEMA WC70, ICEA S-66-524/NEMA WC7 Cross Linked Polyethylene Insulated Wire&Cable, UL 854 for Service Entrance Cables (incl. Para. 854-38.7 for 300 hr. sunlight resistance) and UL 44 for Thermoset Insulated Wires & Cables, Fed Spec J-C-30B, FAA L-824 Type C 600V Connductors: The single copper conductors shall be solid or stranded annealed or hard uncoated copper per UL83 and ASTM requirements. Insulation: The conductor shall be insulated with XLP or XLP-VW-1 as specified and applied tightly to the conductor in a concentric manner. These conductors are “Oil and Gasoline Resistant II”. All black insulation is rated and identified “Sunlight Resistant”. The minimum at any point shall not be less than 90% of the specified average thickness in compliance with UL 44. Identification: The wire shall be identified in compliance with UL requirements by surface marking indicating the manufacturer, conductor size, voltage rating, UL symbol, and type designation.
7
SKU   700-211
Your Price   $216.00
Qty
Product  

AmerCable Wire 10AWG Single-Insulated (red/black/white) (USE-2) - 500FT. Reel

Product Summary   PLEASE SPECIFY COLOR. AmerCable Wire 10awg White Cable Features Scope: This specification describes single conductor crosslinked polyethylene (XLP or XLPE) Type RHW-2 and USE-2 for use at 600 volts or less. It is approved per the NEC for DIRECT BURIAL, general-purpose lighting, and power applications at a maximum continuous operating temperature of 90 degrees C in wet and dry locations. Note: VW-1 available when required. Applicable Standards: ASTM B-1, B-3, and B-8 for copper conductors. ICEA S-95-658/NEMA WC70, ICEA S-66-524/NEMA WC7 Cross Linked Polyethylene Insulated Wire&Cable, UL 854 for Service Entrance Cables (incl. Para. 854-38.7 for 300 hr. sunlight resistance) and UL 44 for Thermoset Insulated Wires & Cables, Fed Spec J-C-30B, FAA L-824 Type C 600V Connductors: The single copper conductors shall be solid or stranded annealed or hard uncoated copper per UL83 and ASTM requirements. Insulation: The conductor shall be insulated with XLP or XLP-VW-1 as specified and applied tightly to the conductor in a concentric manner. These conductors are “Oil and Gasoline Resistant II”. All black insulation is rated and identified “Sunlight Resistant”. The minimum at any point shall not be less than 90% of the specified average thickness in compliance with UL 44. Identification: The wire shall be identified in compliance with UL requirements by surface marking indicating the manufacturer, conductor size, voltage rating, UL symbol, and type designation. AmerCable Wire 10awg White Cable Features Scope: This specification describes single conductor crosslinked polyethylene (XLP or XLPE) Type RHW-2 and USE-2 for use at 600 volts or less. It is approved per the NEC for DIRECT BURIAL, general-purpose lighting, and power applications at a maximum continuous operating temperature of 90 degrees C in wet and dry locations. Note: VW-1 available when required. Applicable Standards: ASTM B-1, B-3, and B-8 for copper conductors. ICEA S-95-658/NEMA WC70, ICEA S-66-524/NEMA WC7 Cross Linked Polyethylene Insulated Wire&Cable, UL 854 for Service Entrance Cables (incl. Para. 854-38.7 for 300 hr. sunlight resistance) and UL 44 for Thermoset Insulated Wires & Cables, Fed Spec J-C-30B, FAA L-824 Type C 600V Connductors: The single copper conductors shall be solid or stranded annealed or hard uncoated copper per UL83 and ASTM requirements. Insulation: The conductor shall be insulated with XLP or XLP-VW-1 as specified and applied tightly to the conductor in a concentric manner. These conductors are “Oil and Gasoline Resistant II”. All black insulation is rated and identified “Sunlight Resistant”. The minimum at any point shall not be less than 90% of the specified average thickness in compliance with UL 44. Identification: The wire shall be identified in compliance with UL requirements by surface marking indicating the manufacturer, conductor size, voltage rating, UL symbol, and type designation.
8
SKU   705-001
Your Price   $10,600.00
Qty
Product  

Studer Cable 10AWG TUV (european) rated-PV WIRE - 20,000FT. Reel

Product Summary   Double insulated, electron-beam cross-linked cables for solar power applications. Construction Conductor: Tinned fine copper strands, according to VDE 0295 / IEC 60228, class 5 Insulation: Polyolefin Copolymer electron-beam cross-linked Outer sheath: Polyolefin Copolymer electron-beam cross-linked Sheath colour: Black Technical specification Nominal voltage: U0/U = 600 / 1000 V AC, 1000 / 1800 V DC Test voltage: 4000 V, 50 Hz, 5 min. Temperature rating: – 40 °C up to + 125 °C Ambient temperature: > 25 years (TÜV) – 40 °C up to + 90 °C – 40 °F up to + 194 °F Max. short circuit temperature: 280 °C, + 536 °F Bending radius: ≥ 4 × outer Standards / Material properties Fire performance: IEC 60332-1; UL 1581 1061 / VW1 Smoke emission: IEC 61034; EN 50268-2 Low fire load: DIN 51900 Approvals: TÜV PfG 1169/08.2007 PV1-F; UL 4703 PV wire; UL 854 USE-2 Application standards: NEC 2008 / UL PV wire, USE-2; UNE 21123; UNE 20.460-5-52, UTE C 32-502
9
SKU   705-002
Your Price   $7,600.00
Qty
Product  

Studer Cable 12AWG TUV (european) rated-PV WIRE - 20,000FT. Reel

Product Summary   Double insulated, electron-beam cross-linked cables for solar power applications. Construction Conductor: Tinned fine copper strands, according to VDE 0295 / IEC 60228, class 5 Insulation: Polyolefin Copolymer electron-beam cross-linked Outer sheath: Polyolefin Copolymer electron-beam cross-linked Sheath colour: Black Technical specification Nominal voltage: U0/U = 600 / 1000 V AC, 1000 / 1800 V DC Test voltage: 4000 V, 50 Hz, 5 min. Temperature rating: – 40 °C up to + 125 °C Ambient temperature: > 25 years (TÜV) – 40 °C up to + 90 °C – 40 °F up to + 194 °F Max. short circuit temperature: 280 °C, + 536 °F Bending radius: ≥ 4 × outer Standards / Material properties Fire performance: IEC 60332-1; UL 1581 1061 / VW1 Smoke emission: IEC 61034; EN 50268-2 Low fire load: DIN 51900 Approvals: TÜV PfG 1169/08.2007 PV1-F; UL 4703 PV wire; UL 854 USE-2 Application standards: NEC 2008 / UL PV wire, USE-2; UNE 21123; UNE 20.460-5-52, UTE C 32-502
9 Products: Page 1 of 1
 

Home - Learning Center - Homeowners - Commercial - Contact Us - Terms & Conditions - CSI Modules - - Sharp Solar Modules -ASI Modules -  - Grid Tie Inverters - GTI W/ Battery Backup - Off Grid Inverters - Inverter Accessories - PrePackaged Systems - Charge Controllers - PV Tools - Solar Pro - Top 50 Solar - State Rebates - Aten Blog - Become a Dealer