SMA Windy Boy 6000A - 6000W, Wind Inverter, specify turbine, WB 6000A Features
Technical data Windy Boy 5000A Windy Boy 6000A
Input (DC)
Max. DC power 5750 W 6300 W
Recommended generator power at 2500 / 5000 full-load hours per year 4600 W / 4200 W 5500 W / 5100 W
Max. DC voltage 600 V 600 V
DC nominal voltage 270 V 270 V
Min. open circuit voltage for activating “Turbine Mode” 300 V 300 V
Operating range “Turbine Mode” 250 V – 600 V 250 V – 600 V
Max. input current 26.0 A 26.0 A
Output (AC)
AC nominal power 5000 W 6000 W
Max. AC power 5500 W 6000 W
Max. output current 26.0 A 26.0 A
Nominal AC voltage / AC operating range 220 V, 230 V , 240 V / 180 V – 260 V
AC grid frequency / range 50 Hz, 60 Hz / ± 4.5 Hz 50 Hz, 60 Hz / ± 4.5 Hz
Power factor (cos ϕ) 1 1
Phase conductors / connection phases 1 / 1 1 / 1
Efficiency
Max. efficiency / Euro-Eta 96.1 % / 95.3 % 96.1 % / 95.3 %
Protective devices
DC reverse-polarity protection ● ●
AC short-circuit protection ● ●
Ground fault monitoring ● ●
Grid monitoring (SMA Grid Guard) ● ●
Galvanically isolated ● ●
Protection class / overvoltage category I / III I / III
General data
Dimensions (W / H / D) in mm 468 / 613 / 242 468 / 613 / 242
Weight 62 kg 63 kg
Operating temperature range –25 °C ... +60 °C –25 °C ... +60 °C
Noise emission (typical) ≤ 42 dB(A) ≤ 42 dB(A)
Internal consumption: operation / standby < 7 W / 0.25 W < 7 W / 0.25 W
Topology LF transformer LF transformer
Cooling concept OptiCool OptiCool
Electronics protection rating / connection area (per IEC 60529) IP65 / IP65 IP65 / IP65
Climatic category (per IEC 60721) 4K4H 4K4H
Features
DC connection: SUNCLIX ● ●
AC connection: screw terminal ● ●
Display: text line / graphic ●/— ●/—
Interfaces: RS485 / Bluetooth® ○/○ ○/○
Warranty: 5 years / 10 years ●/○ ●/○
Certificates and permits CE, VDE0126-1-1, G83/1, CER/06/190, DK 5940 ED2.2*,
RD 1663, AS4777, EN 50438
* applies only to IT variant
● Standard features ○ Optional features — Not available / Data at nominal conditions
Type name WB 5000A WB 6000A